EIA-310-E High-Density 42U Enclosures · 15-Minute Formal Quote Turnaround
MODEL CODE R42-8120SERIES AI GPU FLAGSHIPCATEGORY 42U Extra-Deep AI Racks

R42-8120 — 42U 800×1200 mm Extra-Deep AI GPU Server Rack Enclosure

Flagship 800 mm wide × 1,200 mm deep (31.5 × 47.2 in) 42U enclosure engineered for high-density AI training nodes, dual vertical intelligent PDUs, and front-to-rear high-CFM cooling.

Request 15-Minute Formal Quote WhatsApp +86 13392250172Email jacklau@42urack.com

Dual-Unit Technical Specifications (R42-8120)

ParameterEngineering SpecificationReference / Notes
Rack Height42U usable (1,866.9 mm / 73.5 in)Exterior height 2,000 mm (78.7 in) on levelers; 2,055 mm with casters
External Width × Depth800 × 1,200 mm (31.5 × 47.2 in)Matches Vertiv VR3350 & 800 mm data hall baying pitch
Adjustable Rail Depth180 – 1,040 mm (7.1 – 40.9 in)4× heavy-gauge 2.0 mm steel L-rails with laser-etched U markings
Static / Rolling Load1,500 kg (3,307 lb) static / 1,100 kg (2,425 lb) rollingBuilt to EIA-310-E dimensional and static-load engineering standards
Perforation Open Area> 78% hexagonal meshSingle curved/flat front door + space-saving split rear doors
Zero-U PDU Channels2× rear vertical channels (supports up to 4× 0U PDUs)Tool-less keyhole button mounts + full-height cable fingers
Top & Bottom Cable Entry4× brush-grommet roof cutouts + open base with optional solid bottomSized for overhead busway whips and 400G/800G fiber trunks
Frame & FinishSPCC cold-rolled welded steel, RAL 9005 matte blackOptional RAL 9003 signal white for high-visibility cold aisles

Target Applications & Operating Fit

  • 4U to 8U AI GPU compute servers (850–960 mm chassis depth) requiring unobstructed rear PSU and InfiniBand bend clearance
  • High-density virtualization and storage clusters running 15–30 kW per cabinet in hot/cold aisle containment rows
  • Enterprise data halls standardizing on 800 mm cabinet width for side-channel vertical patch routing and zero-U intelligent PDUs
  • Drop-in dimensional replacement or expansion alongside Vertiv VR3350 and Eaton SmartRack 42U Extra-Deep rows

Structural & Standards Engineering

  • Built to EIA-310-E dimensional and static-load engineering standards; structural load test documentation available per project
  • Continuous vertical cable management channels along both 19-inch front rail sides with removable finger covers
  • Split rear perforated doors cut rear aisle swing radius in half (400 mm swing per leaf vs. 800 mm single door)
  • Integrated baying brackets on frame corners enable gap-free row alignment on 800 mm data center tile centers
  • Pre-bonded M6 grounding studs across frame, doors, and split side panels for unified chassis equipotential bonding

5-Parameter Engineering Modification Scope

  • Color finish: RAL 9005 matte black (standard) or RAL 9003 white for improved aisle lighting reflectance
  • Locking systems: 3-point keyed swing handle, 4-digit mechanical combination, or RFID/electronic smart handle cutouts
  • Roof panel architecture: custom brush grommet positions, overhead ladder-tray brackets, or passive exhaust chimney interface
  • Pre-installed accessories: 1U/2U tool-less blanking panels, 150 kg sliding shelves, and horizontal brush managers
  • Side panel deletion: order without side panels for interior row positions in bayed 4–20 rack deployments

Technical FAQs

Will an 8U 920 mm deep GPU server fit inside the R42-8120 with rear PDUs installed?

Yes. With 1,200 mm (47.2 in) external depth and 800 mm (31.5 in) width, the R42-8120 mounts vertical Zero-U PDUs in the outer side channels behind the 19-inch rail plane, leaving ~220 mm behind a 920 mm chassis for redundant power cords and DAC/optical cable bend radius.

Does the R42-8120 bay flush next to existing 800×1200 mm racks such as Vertiv VR3350?

Yes. The exterior 800 mm width and 1,200 mm depth match standard 800×1200 mm data hall floor layouts. Confirm your existing row height (2,000 mm vs. 2,055 mm) in your 15-minute quote brief so leveling feet and baying brackets align cleanly.

How many Zero-U vertical PDUs can be mounted without blocking server hot-swap power supplies?

Each rear vertical channel accepts two standard 56 mm wide 0U PDUs side by side (up to four 0U PDUs total) outboard of the 19-inch equipment envelope, preserving straight-back extraction of redundant PSUs and rear fan modules.

What documentation is supplied for structural load verification?

The R42-8120 is built to EIA-310-E dimensional and static-load engineering standards; structural load test documentation is available per project along with a signed dimensional approval drawing before fabrication.

R42-8120-HD

42U 800×1200 mm 2,000 kg Heavy-Load Server Rack

Reinforced 800×1200 mm 42U welded frame engineered for 2,000 kg (4,409 lb) static loads, liquid-cooling manifolds, and seismic-ready anchoring.

View Datasheet →
R42-6110

42U 600×1100 mm Standard High-Density Server Rack

600×1100 mm standard high-density 42U rack aligned to 24-inch floor tiles with 1,500 kg static load and >78% hex-mesh ventilation.

View Datasheet →
R42-2B

42U 2-Bay (2×20U) Multi-Tenant Colocation Cabinet

42U 2-Bay (2×20U) colocation cabinet with solid steel tenant separation, independent front/rear locking, and isolated rear cable channels.