EIA-310-E High-Density 42U Enclosures · 15-Minute Formal Quote Turnaround
MODEL CODE R42-2BSERIES 2-BAY COLOCATIONCATEGORY Multi-Bay Colocation Cabinets

R42-2B — 42U 2-Bay (2×20U) Independent Locking Colocation Cabinet

Two physically isolated 20U tenant compartments inside a single 42U footprint—engineered with solid steel inter-bay security dividers, independent front/rear door locks, and dedicated tenant cable risers.

Request 15-Minute Formal Quote WhatsApp +86 13392250172Email jacklau@42urack.com

Dual-Unit Technical Specifications (R42-2B)

ParameterEngineering SpecificationReference / Notes
Compartment Layout2 independent bays × 20U each (40U net + 2U divider)Solid 1.5 mm bolted/welded steel mid-shelf blocks inter-bay reach
External Width × Depth800 × 1,200 mm (31.5 × 47.2 in)Also configurable in 600 × 1,070 mm or 600 × 1,200 mm
Static / Rolling Load1,360 kg (3,000 lb) static / 1,020 kg (2,250 lb) rollingBuilt to EIA-310-E dimensional and static-load engineering standards
Perforation Open Area> 78% hexagonal mesh per compartment door2× independent front doors + 2× independent rear doors
Compartment LockingUnique keyed 3-point swing handles (or 3/4-digit combo / RFID)Zero shared latch rods between upper and lower tenant bays
Isolated Cable Channels2× enclosed lockable steel rear vertical risersUpper tenant routes top-down; lower tenant routes through sealed chute
Zero-U PDU Capacity1–2 half-height 0U PDUs per bay (20U vertical brackets)Separate A/B metered power per tenant bay
Side PanelsInternally bolted solid steel side panelsPrevents unauthorized removal from outside the locked bay

Target Applications & Operating Fit

  • Retail colocation providers selling half-cabinet (20U) allocations without dedicating a full floor tile per customer
  • Compliance-sensitive hosting (PCI-DSS, SOC 2, HIPAA) requiring physical steel separation between adjacent tenants
  • Carrier hotels and edge PoPs deploying dual-tenant 1,200 mm deep storage or GPU servers in half-rack increments
  • Operators expanding or cross-referencing Eaton SR42UBCL or Hammond CLC 2-Bay colocation rows

Structural & Standards Engineering

  • Built to EIA-310-E dimensional and static-load engineering standards; structural load test documentation available per project
  • Enclosed steel rear vertical cable manager security covers prevent upper/lower tenants from accessing neighbor fiber or power whips
  • Internally secured side panels cannot be removed while tenant doors are locked, maintaining physical perimeter integrity
  • Dedicated front and rear compartment doors allow one tenant to service servers without unlocking the second bay
  • Independent 20U adjustable mounting rails let upper and lower tenants set different rail depths for mixed server chassis

5-Parameter Engineering Modification Scope

  • Access control: unique keyed cylinders, 4-digit mechanical combination handles, or electronic keypad/RFID card handles
  • Footprint choice: 800 × 1,200 mm (maximum rear riser room) or 600 × 1,070 / 1,200 mm (1-tile colocation rows)
  • Solid bottom panel kit with brush cable entry for slab-floor or raised-floor plenum isolation
  • Custom laser-engraved bay identification plates (Bay A / Bay B) and RAL 9005 black or RAL 9003 white finish
  • Passive exhaust chimney adapter for top-plenum hot-aisle return architectures

Technical FAQs

How are cables routed to the lower 20U bay without passing openly through the upper tenant's compartment?

The R42-2B includes dedicated enclosed steel vertical cable risers with lockable security covers along the rear corners. Power whips and fiber trunks enter from the roof (or raised floor) and travel inside the sealed steel conduit directly to the lower bay.

Can the upper and lower 20U bays have different mounting rail depths?

Yes. Each 20U compartment uses independent front and rear EIA-310-E vertical mounting rails, allowing one tenant to mount a 600 mm network stack while the other mounts 900 mm deep compute nodes.

Do the four doors use unique keys or electronic RFID locks?

Standard units ship with uniquely keyed 3-point swing handles per bay (front and rear of Bay 1 share Key A; Bay 2 shares Key B) with a master override option. Mechanical combination or RFID/keypad handles can be factory-fitted.

Is a 600 mm wide version available for legacy 24-inch colocation rows?

Yes. While 800 × 1,200 mm provides the most generous isolated riser volume for dual-feed PDUs and high-strand fiber, we also manufacture the R42-2B in 600 × 1,070 mm and 600 × 1,200 mm footprints.

R42-8120

42U 800×1200 mm Extra-Deep AI GPU Server Rack

800×1200 mm extra-deep 42U AI GPU flagship with 1,500 kg (3,307 lb) static load, >78% hex-mesh airflow, and dual rear Zero-U PDU channels.

View Datasheet →
R42-8120-HD

42U 800×1200 mm 2,000 kg Heavy-Load Server Rack

Reinforced 800×1200 mm 42U welded frame engineered for 2,000 kg (4,409 lb) static loads, liquid-cooling manifolds, and seismic-ready anchoring.

View Datasheet →
R42-6110

42U 600×1100 mm Standard High-Density Server Rack

600×1100 mm standard high-density 42U rack aligned to 24-inch floor tiles with 1,500 kg static load and >78% hex-mesh ventilation.

View Datasheet →