R42-4B — 42U 4-Bay (4×9U/10U) Multi-Tenant Colocation Server Cabinet

Four physically segregated quarter-rack compartments inside a single 42U enclosure—built for edge PoPs, carrier interconnections, and managed colocation operators maximizing revenue per floor tile.

Request 15-Minute Formal Quote WhatsApp +86 13392250172Email jacklau@42urack.com

Dual-Unit Technical Specifications (R42-4B)

ParameterEngineering SpecificationReference / Notes
Compartment Layout4 independent bays × 9U usable (4×10U low-profile option)3× solid 1.5 mm steel horizontal dividers block all inter-bay access
External Width × Depth600 × 1,200 mm (23.6 × 47.2 in)Also configurable in 800 × 1,200 mm for high-density fiber risers
Static / Rolling Load1,360 kg (3,000 lb) static / 1,000 kg (2,205 lb) rollingBuilt to EIA-310-E dimensional and static-load engineering standards
Doors & Perforation4× front + 4× rear independent >78% hex-mesh doors180° door opening with concealed tamper-resistant hinges
Locking Hardware4× unique keyed locks, 4-digit combo, or smart RFID handlesFront and rear doors paired per tenant bay (Bays 1–4)
Cable Routing Security4× dedicated enclosed rear vertical cable channelsEach bay connects to roof/floor via isolated pass-through baffle
Power Integration1U horizontal PDU per bay (or compact vertical PDU in 800 mm)Supports independent A/B metered circuits per tenant
Finish & MarkingRAL 9005 matte black or RAL 9003 whiteLaser-etched U markings inside every compartment

Target Applications & Operating Fit

  • Quarter-rack colocation suites hosting four separate enterprise or MSP tenants within one 600 mm or 800 mm floor tile
  • Regional telecom PoPs, IXP peering nodes, and CDN edge caches requiring 6U–9U per carrier
  • Multi-department government, university, or healthcare data rooms enforcing physical access segregation
  • Managed hosting providers migrating from open shared cabinets to audit-ready physical compartment isolation

Structural & Standards Engineering

  • Built to EIA-310-E dimensional and static-load engineering standards; structural load test documentation available per project
  • Solid horizontal steel security dividers prevent physical reach or dropped-fastener interference between stacked bays
  • Concealed hinges and internally bolted side panels defeat exterior tampering in shared colocation corridors
  • Four independent rear cable channels isolate tenant fiber patch cords and A/B power feeds from roof to floor
  • Full >78% hexagonal perforation on all eight doors preserves front-to-rear laminar airflow without cross-bay thermal bleed

5-Parameter Engineering Modification Scope

  • 800 mm wide upgrade (800 × 1,200 mm) when tenants require extra side-channel vertical cable and 0U PDU room
  • Electronic keypad, RFID proximity card, or networked DCIM access lock cutouts on all 8 doors
  • 3-Bay (3 × 13U) custom divider configuration available on the same 42U frame
  • Solid floor base with brush cable plates for raised-floor bypass airflow containment
  • Factory-fitted 1U metered horizontal PDU rails and bay-specific blanking panel kits

Technical FAQs

How much usable rack space does each bay have in a 4-Bay 42U cabinet?

Standard heavy-divider construction yields 4 × 9U usable (36U net across four bays, with 6U allocated to structural horizontal dividers and door frames). Our slim-divider profile provides 4 × 10U usable where lighter switches and 1U servers are deployed.

Should we choose 600 mm or 800 mm width for a 4-Bay colocation rack?

Choose 600 × 1,200 mm when maximizing cabinet count along 24-inch floor tiles with standard 1U horizontal PDUs and moderate fiber counts. Choose 800 × 1,200 mm when four tenants need separate enclosed rear vertical cable channels and side-mounted vertical PDUs.

Can we order a 3-Bay (3 × 13U) variant on the same 42U frame?

Yes. Both 3-Bay (3 × 13U) and asymmetric split (e.g., 1 × 20U + 2 × 9U) configurations are engineered on the same 42U frame—note your desired bay U-allocation in your 15-minute formal quote request.

How are the eight doors locked and managed for data center security audits?

Each tenant bay's front and rear doors share a dedicated lock code (Bay 1 through Bay 4) distinct from the other three bays. Optional combination handles or RFID/electronic swing handles integrate with colocation access logs.

R42-8120

42U 800×1200 mm Extra-Deep AI GPU Server Rack

800×1200 mm extra-deep 42U AI GPU flagship with 1,500 kg (3,307 lb) static load, >78% hex-mesh airflow, and dual rear Zero-U PDU channels.

View Datasheet →
R42-8120-HD

42U 800×1200 mm 2,000 kg Heavy-Load Server Rack

Reinforced 800×1200 mm 42U welded frame engineered for 2,000 kg (4,409 lb) static loads, liquid-cooling manifolds, and seismic-ready anchoring.

View Datasheet →
R42-6110

42U 600×1100 mm Standard High-Density Server Rack

600×1100 mm standard high-density 42U rack aligned to 24-inch floor tiles with 1,500 kg static load and >78% hex-mesh ventilation.

View Datasheet →